Analog Input / Output Modules
Analog input modules AI20x/SI
- Number of inputs: 2 / 8
- Input current: 0 .. 20 mA
- Differential inputs
- Resolution: 13...16 bit
- Galvanic isolation from system: 500 V
- Galvanic isolation of channels: 500 V
Analog input modules AI204/x
- Number of inputs: 1 / 2 / 4
- Input voltage: ±10 V DC
- Differential inputs
- Resolution: 16 bit
- Inputs can be synchronized
- Galvanic isolation from system: 500 V
- Galvanic isolation of channels: 500 V
Analog input modules AI208/SI
- Number of inputs: 8
- Input current: 4 .. 20 mA, 0 .. 20 mA, -20 .. +20 mA
- Resolution: 13 .. 16 Bit
- Galvanic isolation from system: 500 V
- Galvanic isolation of channels: 500 V
Analog output module AO202
Number of outputs: 2
Output voltage: ±10 V DC
Differential and short circuit proof outputs
Resolution: 16 bit
Outputs can be synchronized
Galvanic isolation from system: 500 V
Galvanic isolation of channels: 500 V
Analog output module AO208/l
- Number of outputs: 8
- Output current: 0 .. 20 mA or 4 .. 20 mA
- Resolution: 13 bit
- Galvanic isolation from system: 500 V
- Galvanic isolation of channels: 500 V
Analog output modules AO20x/SI
- Number of outputs: 2 / 4
- Output current: 0 .. 20 mA
- Differential outputs
- Short circuit proof outputs
- Resolution: 16 bit
- Galvanic isolation from system: 500 V
- Galvanic isolation of channels: 500 V
Analog I/O modules AIO288/x
- Number of inputs:
- 8 (±10 V DC / ±1 V DC or 0 .. 20 mA)
- Number of outputs: 8 (±10 V DC)
- Resolution: 14 bit
- Connection: single-ended or differential
- Number of Pt100 sensors: 4
- Connection: 2- or 4-wire technology
- Optional galvanic isolation from system: 500 V
Temperature recording module PTAI216
- Number of inputs: 4 (±10 V DC / ±1 V DC or 0 .. 20 mA)
- Connection: single-ended or differential
- Resolution: 14 bit at AI
- Number of Pt100/Pt1000 sensors: 12
- Connection: 2-wire technology
- Resolution: 12 bits with Pt100/Pt1000
- Galvanic isolation from system: 500 V
Temperature recording modules TI214/x
- TI214: 14 inputs for Pt100 / Pt1000 sensors as well as type J or K thermocouples
- TI214/2: thermal couples type N or S
- Resolution 14 bit (16 bit with measured value filtering)
- Wire break detection on the measurement inputs
- Galvanic isolation from system: 500 V
Strain gauge module DMS202
- Number of strain gauge (DMS) measuring inputs: 2 (full bridge)
- Industrial connectors (LEMO)
- Analog measuring outputs: 2
- Automatic measuring range selection
- Wire break detection on the measurement inputs
- Resolution: 12 bit
- Galvanic isolation from system: 500 V