Telecontrol Protocol

IEC 60870-5 Client and Server (Master and Slave)

IEC 60870-5 Client and Server (Master and Slave)

For communication in accordance with IEC 60870-5-101, -103 and -104

  • Standard compliant implementation of IEC 60870-5-101, -103, -104 client and server
  • Subsequently installable service/software solution
  • No changes to the application logic required
  • Fully configurable/no application-specific processing via PLC libraries required
  • Configurator for commissioning and diagnostic monitor in the SolutionCenter
  • Import/export of the slave configuration in CSV format for exchange with other manufacturers
  • Reducing the amount of data via configurable threshold filters
  • Number and IP addresses of authorized clients can be limited
  • Logging of write accesses in the security log of the controller
  • Easy and fast start-up including diagnosis without any programming effort
  • The remote control protocol can be operated like a simple I/O module

Interoperability documents:


MMS Server (IEC 61850 / IEC 61400-25)

MMS Server (IEC 61850 / IEC 61400-25)

Manufacturing Message Specification Server

  • Communication in accordance with standards IEC 61400-25 or IEC 61850
  • Pure software solution, special additional hardware is unnecessary
  • Shared operation with other protocols on the same Ethernet interface
  • Enables access from outside to variables of the controller

MMS Client (IEC 61850 / IEC 61400-25)

MMS Client (IEC 61850 / IEC 61400-25)

Manufacturing Message Specification Client

  • Communication in accordance with standards IEC 61400-25 or IEC 61850
  • Pure software solution, special additional hardware is unnecessary
  • Shared operation with other protocols on the same Ethernet interface
  • Enables access from outside to variables of the controller

DNP3

DNP3

Distributed Network Protocol

DNP3 service for master and outstation

  • Complies with Level 2 with some extensions from Level 3 and 4
  • Requires for operation on the controller a license file for master, outstation or both simultaneously
  • Uses the Ethernet ports and/or serial COM ports of the controller
  • Support for unsolicited responses
  • Support for time synchronization via DNP3

DNP3 outstation

  • Configuration of data objects via CSV file
  • Linking of data objects with existing process variables
  • Parallel connection with several masters possible (requires the configuration of several instances)
  • Automatic deadband calculation (threshold value filtering) of analog actual values to reduce the data volume
  • Time stamp of value changes implicit via the service
  • Formation of quality information (flags) implicit via the service, can be set additionally by the application via a quality variable
  • Quality ensured by standardized certification tests

DNP3 master

  • Access to data objects of the outstation via logical UFB modules
  • The currently received values are provided in the process image
  • All events with flags and time stamp can be read via the function
  • Event-driven handling of received actual values possible